Tel: 631-968-0084
Fax: 631-968-0184
info@cmsheattransfer.com

Homepage
About CMS / Contact
Literature

CMS Services
Design & Selection
Fixed Tubesheet Exchangers

Product Gallery
Advantages & Limitations
U-Tube Exchangers

Download Our Facilities Brochure
CMS_Shop_Survey.pdf (827k)

Product Photo Gallery

Download Acrobat (PDF) Specification Sheet CMS_Design_Selection.pdf (601kb)

Heat Exchanger Designs and Selections Differential Thermal ExpansionPass Arrangements for Flow Through TubesShell Side Fluid Flow
Impingement Plates (based on application)Maintenance and Servicing ConsiderationsPrincipal ComponentsHeat Exchanger Tubes
Materials of ConstructionEconomic Considerations in Heat Exchanger SelectionHeat Exchanger Rating versus Expected Loads
Fundamental Heat TransferLoad is the Measure of Heat TransferredA Combination of Three Factors Governs Load Capacity
Heat Transfer Coefficient (U) Depends on Many VariablesArea is the Total Effective Tube Area

Pass Arrangements for Flow Through Tubes

The simplest flow pattern through the tubes is for the fluid to enter at one end and exit at the other, this is a single pass bundle. This configuration is required when a temperature cross is experienced in the process. However, conditions generally do not make a single pass on the tube side a preferred choice.

Increasing flow velocity and turbulence prevent formation of stagnant films of fluid on the tube surfaces. Thus, higher velocities improve the heat transfer rate. This means increasing the number of tube side passes - that is, directing the flow back and forth through the tubes in the bundle with partitions built into the heads of the exchanger.

There are some limitations on how the different types of heat exchangers can be partitioned to provide various numbers of passes.

With the “U”-tube exchanger, a single pass is not possible because the fluid must traverse the bundle at least twice. Any practical even number of the passes can be obtained by building partition plates in the front head.

With the floating head pull-through bundle type, any practical even number of passes is possible. For single pass operation, however, a packed joint must be installed on the floating head.

The fixed tubesheet type can be used for any practical number of passes, odd or even. For multi-pass arrangements, partitions are built into both heads.

CMS Heat Transfer Division, Inc.
55 Greene Street • Bay Shore, NY 11706-7023 USA
Tel: 631-968-0084 • Fax: 631-968-0184 • Email: info@cmsheattransfer.com